An Evaluation of Energy-Dissipating InletsBy: John K. Esler, P.E., PresidentCPE Services, Inc.
The first two types, gated opening and scooped opening, are in general use and are available from most manufacturers of clarifier equipment. Proponents of the gated EDI mention the flexibility of the gate positioning as an operability advantage. Although I have seen one operation that has changed several of its gates to the fully-open position to encourage the scum to be shunted to the peripheral scum relief slots on the centerwell, virtually every other gated EDI that I've seen has probably never been adjusted.
The scooped EDI is becoming more prevalent. The scoop is reported to be designed with certain dimensions that impart just the right amount of tangential energy to the MLSS to enhance flocculation.
One of the questions facing a designer of either of these types of EDI's is "which direction should they be facing ….. with the rotation of the collector mechanism? ….. or counter to its rotation? Although I used to feel that these inlets should be facing counter to the rotation, I now believe that there probably isn't "a dime's worth of difference".
We have evaluated several clarifier systems with these types of EDI's. Our evaluations have led me to believe that they may not bring an overall benefit to a clarifier. Worse than that, we have found, in a well-controlled, side-by-side full scale evaluation at the LA-Hyperion plant, that the addition of a “scooped” EDI clearly made that clarifier work worse than a control clarifier that had no EDI. (ref. WEFTEC ’99 presentation)
Prior to this project, our own evaluations have shown us that:
Considering these experiences and observations, along with our knowledge of the Phoenix 91st Street project, the Central Weber (UT) project and the Santa Rosa (CA) project (ref. WEFTEC ’02 presentation), I cannot recommend the installation of either of these types of EDI's.
The third type of EDI, made up of multiple plates, is a proprietary device of US Filter's, called the FEDWA. I have not seen one of these in action, and do not know of any installations of these on clarifiers in the 100' diameter range. The device is designed to enhance flocculation by providing for multiple changes in direction of the MLSS. My main concern would be with the hydraulic regime created in the centerwell area. I see nothing in this design that leads me to believe that it would encourage good blanket formation within the centerwell area.
The fourth type of inlet, which makes use of opposing jets to enhance flocculation and reduce any spiraling motion within a clarifier, is also a patented device2 This inlet device was demonstrated in extensive field testing at the Los Angeles-Hyperion plant to increase the capacity of the existing clarifier by more than 50 percent. It did this by responding to the problem of poor blanket formation within the centerwell area and while reducing the intensity of the density currents.
With respect to the #### #### clarifiers, information from Royce vertical solids profiling indicates that there is poor formation of the sludge blanket in the center of these clarifiers. This is the kind of condition that moves the settled sludge deposits further out in a clarifier and eventually leads to clarifier failure. Often mistaken as a “thickening” failure, it is really problem of turbulence. In order to address this condition, and provide other benefits such as enhanced flocculation and better flow distribution, I recommend the use of the opposing-jet “LA-EDI”.